PROGRAMMING
SECURITY AND ARMING
Setting
Arm Stay - No Delay
Auto Exit Time Extension
Keyfob Instant Arming
Keyfob Alarm Disarm
Keyfob Disarming
Engineer' s Reset
Allow Master Code to Access
Security and Arming
Normal Entry Delay
Default
Enabled
Arm stay immediately with no countdown timer
Automatically extend countdown timer if delay door is opened during countdown process a
Enabled
second time
Enabled
When enabled, turns off exit delay if keyfob is used to arm the system
Disabled
When enabled this will Allow a keyfob to disarm alarm events.
Enabled
When Disabled, a Keyfob will not be able to disarm the panel
If a confirmed alarm occurs on a burglary zone, the system is locked out after disarming until a 5
Disabled
digit reset code provided by the installer is entered in.
Allow the master code to access these features and settings.
Disabled
NOTE: this option shall be disabled for UL/cUL. This option shall be enabled for UL Commercial Burg installations.
How much time users have to enter their code after opening a door (30-240secs). With SIA limits
30 Secs
disabled the minimum time can be set to 5 secs.
NOTE: For UL Commercial Burg (UL2610) maximum entry delay should not exceed 60s. For EN Grade 2 it shall not exceed 30 sec.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
Description
44
OF
197