QOLSYS IQ4 Hub Installation Manual page 125

All-in-one 7” (17.8cm) touchscreen
Table of Contents

Advertisement

SYSTEM TESTS
Z-WAVE TESTS
COUNTER
Acked commands no
auto route
Acked commands auto
route
Failed commands
network failed
Network failed
Network not idle
Network no route
Reset All
Details
Command was successful and acknowledged by the sensor; it did not use the normal automatic Z-Wave network route
to execute the command for this device (command was re-routed on the Z-Wave network in order to succeed)
Command was successful and acknowledged by the sensor;  it used the normal automatic Z-Wave network route to
execute the command for this device.
Not possible to transmit data because Z-Wave network is busy (jammed). Command failed to execute.
Not possible to transmit data because Z-Wave network is busy (jammed). Command failed to execute
Auto-routed command failed because Z-Wave network is not yet stable.  Command failed to execute. 
Auto-routed command failed because there is no successful Z-Wave network route to the device.  Command failed to
execute
Resets all counters back to 0 as to better diagnose the network
Shows individual device details such as passed and failed commands. Here you can also reset an individual device' s
counter
QOLSYS CONFIDENTIAL AND PROPRIETARY
DESCRIPTION
PAGE
125
OF
197