PROGRAMMING
SECURITY AND ARMING
Setting
Normal Exit Delay
Long Entry Delay
Long Exit Delay
Default
How much time users have to exit the location before the panel arms itself (30-254secs). With SIA
limits disabled the minimum time can be set to 5 secs. Door/Window group 10 follows the
60 Secs
"Normal Exit Delay"
the maximum exit delay should not exceed 30s.
A second separate entry delay that can be used on a sensor needing more time when tripped
100 Secs
(45-240secs). With SIA limits disabled the minimum time can be set to 5 secs.
EN Grade 2
A second separate exit delay that can be used on a sensor needing more time when tripped
120 Secs
(45-254secs). With SIA limits disabled the minimum time can be set to 5 secs. Door/Window
group 12 follows the "Long Exit Delay".
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
Description
NOTE: For UL Commercial Burg (UL2610) maximum exit delay should not exceed 60s. For EN Grade 2
NOTE: Not for use with EN Grade 2
45
OF
197
NOTE: Not for use with