Appendix B Supplemental Installation Procedures

Defining the Library Power-Up State

32
Defining the Library Power-Up State
You have the option of defining the starting condition of the library,
either On-line or standby ( Off-line ), after power-up, self-tests and
initialization has occurred. The default is On-line . You can change it by
using the Power-Up State sub-menu as follows:
Press and release the Control Panel STANDBY button and verify
1
that the SDA shows System Off-line .
Press and release the SELECT button to enter the Menu Mode.
2
Verify that the following is displayed in the SDA:
3
M e n u :
C o n f i g u r a t i o n . .
Press and release the SELECT button to choose the Configuration
4
menu.
Verify that the following is displayed in the SDA:
5
M e n u : C o n f i g u r a t i
I n q u i r y
button to bypass the SCSI Address menu and verify that
Use the
6
the following is displayed in the SDA:
M e n u : C o n f i g u r a t i
Po w e r - U p S t a t e
Press and release the SELECT button to choose the Power-Up State
7
menu and verify that the following is displayed in the SDA:
M e n u : Po w e r - U p
O n - L i n e <
Note: System On-line is the default. If you want to change the power-up
state to standby mode ( System Off-line ), proceed to Step 8. Otherwise,
exit the menu mode.
Use the
button to bypass the On-Line option and verify that the
8
following is displayed in the SDA:
M e n u : Po w e r - U p
S t a n d b y
With the desired option displayed on Line #2, press and release the
9
SELECT button.