Connecting to the Target System
Connecting the HP E3472A/73A Emulator to the target system
Connecting the HP E3472A/73A Emulator to the target
system
Caution
To prevent the emulator and the target system from being damaged, be sure
to follow the cautions below when handling them.
•
Be sure to turn off the emulator and the target system before
connecting them.
•
Check that the orientation of the QFP socket/adapter and the QFP
cable is correct.
•
To prevent the emulator from being damaged by static electricity,
store and use the emulator in a place resistant to static electricity.
•
Check that the ground line of the emulator and that of the target
system are properly connected.
•
When turning the system on, switch on the target system first and
then the emulator. When turning the system off, switch off the
emulator first and then the target system.
•
When supplying power to the emulator, check that the emulation
probe is plugged into the target system or demo board.
C a u t i o n
Do not apply excessive force to the QFP cable. Doing so may damage the
cable.
42