Appendix C
Managing the display using RS-232

Power state commands

Get command
get powerstate
The display has six power states:
Power state
Description
ON
The display is in normal operating mode.
READY
The screen is off, but the display is ready to turn on when one of the following
occurs:
STANDBY
The screen is off, and the display is in a low power state. The display enters READY
or ON state when one of the following occurs:
This power state is the default energy saving mode for displays set to a non-EU
location.
NOTE
The EU uses "networked standby" to describe this power state.
smarttech.com/kb/171414
Set command
set powerstate[Value]
Where [Value] is one of the following:
=on
l
=ready
l
=standby
l
=powersave
l
NOTE
If the display is in UPDATEON or
UPDATEREADY state, it might not
change power states after receiving the
command.
A user presses the Power button
l
control.
A user picks up a pen or the eraser.
l
You send the set powerstate=on command.
l
The proximity sensors detect people in the room.
l
The proximity sensors detect people in the room.
l
A user presses the Power button
l
control.
You send the set powerstate=ready or set powerstate=on command.
l
Response
powerstate=[Value]
Where [Value] is one of the following:
on
l
ready
l
standby
l
powersave
l
updateon
l
updateready
l
on the convenience panel or the remote