Power State Commands; Input Commands - SMART Board 6000S Series Installation And Maintenance Manual

Hide thumbs Also See for 6000S Series:
Table of Contents

Advertisement

Appendix B
Managing the display using RS-232

Power state commands

Get command
get powerstate

Input commands

Get command
If one display is connected
get input
If multiple displays are connected
[Display],@ get input
Where [Display] is the display's label (A,
B, and so on).
smarttech.com/kb/171414
Set command
set powerstate[Value]
Where [Value] is one of the following:
=on
l
=ready
l
=standby
l
=powersave
l
NOTE
If the display is in UPDATEON or
UPDATEREADY state, it might not
change power states after receiving the
command.
Set command
set input[Value]
Where [Value] is one of the following:
=hdmi1
l
=hdmi2
l
=hdmi3
l
=vga1
l
=ops1
l
=android
l
[Display],@ set input[Value]
Where
[Display] is the display's label (A, B,
l
and so on).
[Value] is one of the following:
l
=hdmi1
o
=hdmi2
o
=hdmi3
o
=vga1
o
=ops1
o
=android
o
Response
powerstate=[Value]
Where [Value] is one of the following:
on
l
ready
l
standby
l
powersave
l
updateon
l
updateready
l
Response
input=[Value]
Where [Value] is one of the following:
hdmi1
l
hdmi2
l
hdmi3
l
vga1
l
ops1
l
android
l
none
l
@,[Display] input=[Value]
Where
[Display] is the display's label (A, B,
l
and so on).
[Value] is one of the following:
l
hdmi1
o
hdmi2
o
hdmi3
o
vga1
o
ops1
o
android
o
none
o
72