Checking The Kill Switch; Checking The Alternator - KTM 50 SX 2010 Repair Manual

Table of Contents

Advertisement

39/IGNITION SYSTEM

Checking the kill switch

22.4

Checking the alternator

22.5
Measure high voltage output of ignition coil against ground.
Ignition coil
Resistance of secondary winding
at: 20 °C (68 °F)
»
If the measured value differs from the setpoint value:
Change the ignition coil.
Fit and connect spark plug connector.
300933-10
Connect the special tool to the multimeter.
Peak voltage adapter (58429042000) (
Info
When using the peak voltage adapter, the measurement range of the multi-
meter must be set to DCV.
Disconnect the ignition coil.
Connect the black measuring lead of the special tool to ground. Connect the red
300960-10
measuring lead to the input plug of the ignition coil.
Activate the kickstarter.
Ignition coil
Ignition coil input connector -
ground
»
If the displayed value does not equal the specification:
Change the ignition coil.
Condition
Fuel tank removed.
Disconnect ignition coil and kill switch.
Measure resistance on cable of kill switch to ground.
Resistance - kill switch not activated
»
If the displayed value does not equal the specification:
Check the wiring harness.
Change the kill switch.
Activate the kill switch.
300986-10
Resistance - kill switch activated
»
If the displayed value does not equal the specification:
Check the wiring harness.
Change the kill switch.
Condition
The fuel tank has been removed.
Disconnect the ignition coil and kill switch.
Measure the resistance of the alternator against ground.
Alternator
Resistance at: 20 °C (68 °F)
»
If the measured value does not equal the specified value:
Check the wiring harness.
Change the alternator.
300985-10
2.025... 2.475 kΩ
p. 145)
≥ 150 V
0 Ω
450... 500 Ω
120