Lenovo ThinkSystem SR635 V3 User Manual page 65

Hide thumbs Also See for ThinkSystem SR635 V3:
Table of Contents

Advertisement

Note: Among 10 x 2.5" configurations, only 10 x 2.5" NVMe (Gen 4) supports closed loop heat sink. 10 x
2.5" AnyBay (Gen 4/ Gen 5) and 10 x 2.5" NVMe (Gen 5) do not support it.
Front bays
• 10 x 2.5" NVMe
• 10 x 2.5" AnyBay
• 10 x 2.5" SAS/SATA
• 8 x 2.5'' SAS/SATA
• 6 x SAS/SATA + 4 x AnyBay
• 6 x SAS/SATA + 2 x AnyBay + 2 x
NVMe
16-EDSFF
• 4 x 2.5'' SAS/SATA
• 4 x 2.5'' NVMe
• 4 x 2.5'' AnyBay
Storage configurations: server models with rear bays
This section provides thermal information for the storage configuration when rear bays (2 x 2.5" SAS/SATA/
NVMe (U.2/U.3)) are installed.
Max. Ambient
Temp.
Front bays
(at sea level)
30°C
• 10 x 2.5" SAS/
SATA
25°C
• 10 x 2.5" NVMe
• 6 x 2.5" SAS/
25°C
SATA + 4 x 2.5"
AnyBay
Notes:
• To support rear 2x2.5" SAS/SATA or NVMe (U.2/U.3) drives, the following conditions need to be met:
– Gen 4 low-profile riser installed in Riser 1
Max.
Processor group (A, B, E)
Ambi-
ent
Temp.
(at sea
level)
B
35°C
45°C
B
40°C
A
25°C
E (except 9654/9654P processors)
30°C
E
35°C
E (9654/9654P/9174F/9554/9554P
processors only)
25°C
E (9654/9654P processors only)
30°C
A
B
45°C
40°C
A
30°C
E (except 9654/9654P/9174F processors)
25°C
E (except 9654/9654P/9174F/9554/9554P
processors)
25°C
E (9554/9554P processors)
30°C
E (9174F/9654/9654P processors only)
35°C
E
Processor group
B
A
E (9654/9654P
processors only)
Fan type
Heat sink
Perf
Perf
Perf
Perf
Perf
Perf
.
Chapter 5
Hardware replacement procedures
Heat
Fan
sink
type
Perf
Std
Perf
Perf
Perf
Perf
CL
note
Perf
CL
note
Perf
CL
note
Perf
Perf
Perf
Perf
Perf
Perf
Perf
Perf
Perf
CL
Perf
CL
Perf
Perf
Perf
Perf
Perf
CL
Perf
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9g7d9h

Table of Contents