8b. Service
- Must be performed by a technician -
126
WMT5DX取扱説明書_EN.indb 126
9
Remove the six Phillips hexagon socket head bolts (with flat and split washers) (M6 x 16), remove
the lCD frames, and replace the lCD monitor.
z Lay a sheet over a flat surface such as a table or the floor, and place the LCD
z
monitor face down on this sheet to prevent damaging the lCD monitor surface while
performing the work.
Phillips hexagon socket head bolt
(with flat and split washers)
(M6 x 16)
To install, perform the procedure in reverse.
LCD frame
LCD monitor