14.3 Icon front cover.
Locate the top flanges of
the bottom front cover
behind the bottom edge
of the fascia. Fix the
sides of the cover to the
fascia bottom corner
brackets with the two
knurled screws provided
(See figure 43).
14.4 Dream fascia.
1. Place the firefront
casting centrally on top
of the hearth in front of the fascia.
2. Place the bottom front cover casting in position.

15. FULL OPERATING CHECKS

15.1 Checking the control settings.

The control position markings on the fascia are shown in figure 44.
Please note:
When first turned on from cold, the flames will appear predominantly blue.
When operating the fire for the first time, some vapours may be given off which
could set off smoke alarms in the vicinity. These vapours are quite normal with new
appliances. They are totally harmless and will disappear after a few hours use.
1. Make sure the control knob is at the off position (At topmost position marked "O"
on the fascia).
2. Slide the control knob to the bottom (ignition) position marked
position to ignite the pilot. The burner should ignite at its lowest setting within 4
seconds of the pilot igniting. Keep at this position for a
further 10 seconds to allow the pilot flame to stabilise.
3. Release the control knob. The control knob should
automatically spring up to the low heat position. If for any
reason the slider control does not spring up, raise the slider
to the topmost (Off) position and investigate why the slider is
not operating correctly. If the flames go out at this stage or
when checking the rest of the setting positions, try the full
lighting sequence again. If the flames fail after two attempts,
investigate the pilot unit.
©
GDC Group Ltd. 2011
INSTALLER GUIDE
Figure 43. Icon bottom front cover location.
Page 36