Full Operating Checks - Valor 639 Installer's Manual

Open decorative gas fire
Hide thumbs Also See for 639:
Table of Contents

Advertisement

Spillage check.
• A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic fuel effect pieces are in position. (See
figure 46 )
• Close all doors and windows in the room containing the appliance. Light the appliance
and set the control to the 'HIGH' position. Leave the appliance on for five minutes.
See lighting instructions within section 5 of this guide.
• Insert the smoke match at least 50mm away from the side of the fireplace opening and
not more than 50mm from the top of the opening. The end of the smoke match should
be level with the front face of the fireplace opening.
• The installation is satisfactory if the smoke is drawn into the fireplace opening. If the
smoke is not drawn into the fireplace opening, leave the appliance alight at the
maximum setting for a further ten minutes and then repeat the test. If smoke is still not
drawn into the appliance disconnect the
appliance and seek expert advice.
• If the above test is satisfactory, open all
internal connecting doors, hatches, etc.
in the room. Keep all doors and
windows that open to the outside of the
building closed. Switch on any extractor
fan installed in the same room as the
appliance or a connecting room. Open
all doors and other openings between the
fan and the appliance. Recheck for
spillage as above. If the smoke is drawn
into the appliance, continue with the
installation. If the test is not satisfactory,
disconnect the appliance and advise the
customer of the cause of failure.
INSTALLER'S GUIDE

10. FULL OPERATING CHECKS

Figure 46. Spillage check
Page 31