13. FIREFRONT CASTING
1. Locate the two screw heads through the keyhole
slots at the inner sides of the surround. If the screw
heads do not project enough or project too far, the
screws can be adjusted. Lower the casting so that it
rests on the hearth. See figure 35.
3. Fit the front cover casting below the front casting.
14.1 Recheck the Control Settings
The control position markings on the front surround
are shown in figure 36.
Please note:
When first turned on from cold, the flames will
!
appear predominantly blue.
When operating the fire for the first time, some
!
vapours may be given off which could set off smoke
alarms in the vicinity. These vapours are quite normal
with new appliances. They are totally harmless and
will disappear after a few hours use.
14.1.1 Lighting the burner
1. Make sure the slider button is at the off position (At
topmost position marked "O" on the front surround).
2. Open the isolating valve on the inlet 'T' connector
3. Slide the button to the bottom (ignition) position marked
to ignite the pilot. The burner should ignite at its lowest setting within 4 seconds of the
pilot igniting. Keep at this position for a further 10 seconds to allow the pilot flame to
stabilise.
4. Release the button. The button should automatically spring up to the low heat
position. If the flames go out at this stage or when checking the rest of the setting
positions, try the full lighting sequence again. If the flames fail after two attempts,
INSTALLER GUIDE

14. FULL OPERATING CHECKS

INSTALLATION
8
Figure 35. Firefront casting
location
Figure 36. Control position
markings
Page 26