P A R T 1 3 : F U L L O P E R A T I N G C H E C K S
Figure 43 Smoke match tube
position
13.1 Recheck Control Settings
Now that all the ceramic fuel effects are in position, the control operation must
be fully rechecked.
13.1.1Make sure that the isolating valve at the inlet elbow is open and that the
electrical power supply is on (the indicator light should glow).
13.1.2Press and hold in the "on" switch. Within two seconds, the Fan motor
should start and the indicator light should go out.
13.1.3Release the "on" switch. The fan should continue to run.
13.1.4Depress the control knob and turn anticlockwise partially towards the
"PILOT/IGN" position until some resistance is felt. Keep depressed at this
position to purge air from the system then, while keeping it depressed, turn
fully to the "PILOT/IGN" position. A spark should be generated at the pilot
while turning. The spark should ignite the pilot. Check that the pilot flame is
visible - See section 12.5.3.
13.1.5When pilot ignition has been achieved, keep the control knob depressed
for approximately ten seconds to allow the thermocouple probe to warm up and
then release it. If the pilot does not remain alight, ensure that the pilot orifice is
clear.
13.1.6When the pilot is alight and stable, partially depress the knob and turn to
"LOW". The pilot should then light the main burner at its low setting. There
may be a delay of up to four seconds between the pilot lighting and ignition of
the gas at the main burner. This is normal and is due to the time required to fill
the main burner compartment with sufficient gas for ignition.
13.1.7When the burner is operating properly, partially depress the knob and
gradually turn it anti-clockwise. The burner flames should gradually increase
until the knob reaches the "HIGH" position.
13.1.8Partially depress the control knob and turn back to "PILOT/IGN". The
main burner flames should be extinguished but the pilot should remain alight.
13.1.9Partially depress the control knob and turn to "OFF". The pilot should be
extinguished
.
13.1.10 Press the "off" switch to turn off the fan (the indicator light should
glow).
13.2 Check For Spillage
A spillage check must be made before leaving the installed appliance with the
customer. Make this check with the appliance fully installed with the ceramic fuel
effects and front surround in position.
13.2.1Close all doors and windows in the room containing the appliance.
13.2.2Turn on the fan. Light the appliance and turn the control knob to
"HIGH".
13.2.3Leave the appliance on for five minutes
13.2.4There are two types of smoke match holders. One has a copper finish,
the other is plain steel. Please apply the relevant parts of the spillage test
instructions.
Place the smoke match tube into the convection box at the right hand side
and immediately below the black top cross member. Angle it at
approximately 45° to the horizontal (figure 43).
Copper finish tubes: Insert the tube so that the raised ring (approx. 25mm
from the end) touches the outside surface of the edge of the cross member.
Plain steel tubes: Insert the tube so that the neck of its flared end touches
the inside surface of the edge of the cross member.
.