Preparing Appliance For Installation; Front Surround Removal - Valor Ultimate Turbochim BR517S Installer's Manual

Side fan flued inset gas fire
Hide thumbs Also See for Ultimate Turbochim BR517S:
Table of Contents

Advertisement

P A R T 4 : P R E P A R I N G A P P L I A N C E F O R I N S T A L L A T I O N
4.1
Cut the fan cable
The appliance is supplied with the fan supply cable linking the fan box to the
convection box unit. To enable the fan unit to be installed to the wall, the cable
will have to be cut. A junction box is supplied for reconnecting the cable after
installation of the fan unit and ducting. The junction box is intended to be fixed
to the wall at the side of the appliance. It should be positioned so that it will be
behind the fireplace surround.
Cut the cable at the point suitable for reconnecting to the junction box. This
will usually be just past the end of the grey abrasion resistant insulation sleeve.
!Always cut the cable before the mains cable is connected to the
electricity supply system
4.2
Check ignition spark
Before attempting to install, it is worth checking that the piezo electric
spark ignition system operates satisfactorily.
To initiate the spark, depress the control knob and while keeping it
depressed, turn anticlockwise through approximately 60° to the
"PILOT/IGN" position. A spark should track from the electrode pin to
the thermocouple tip. If there is no spark or incorrect tracking, check the
spark gap between the electrode wire and thermocouple tip (see figure 5).
If the spark gap is correct, check the ignition wiring.
4.3
Remove the two screws securing the bottom of the front surround
to the sides of the convection box. Raise the front surround to allow the
retaining lugs at the top to clear the slots in the convection box hood and
then lift clear (see figure 6).
4.4
Detach the terminal guard and other fittings from the back of the
convection box by removing two screws and washers. The two screws are
for transit purposes only but the washers will be required to fit the guard to
the fan box outlet - Do not discard them.
4.5
For transit purposes the wall fixing brackets are fitted to the
convection box facing inwards. Remove the brackets and refit them with
the long legs facing outwards (see figure 7).
4.6
In the majority of cases temporary removal of mains cable will make
connection to the isolating switch easier. To allow this, the burner unit will
need to be detached. Detach the burner unit from the convection box by
removing two screws (see figure 8).
Figure 5 Pilot Ignition
Figure 6 Front Surround
Removal
Figure 7
Figure 8 Burner Removal Points
11