6.3 Wall mounting.

The fixing hole positions in relation to
the flue spigot opening are shown in
figure 12. These hole positions are for
the upper fixing brackets shown in figure
13 and the lower fixing holes in the back
panel. Mark these positions on the wall.
The positions can alternatively be
marked by placing the fire in position
and marking the wall through the holes
in the back panel. Drill and plug the
holes using no.10 wall plugs. Place the
fire in position and secure with four no.
10 x 2in. woodscrews.

6.4 Gas supply connection.

8mm rigid tubing must be used to
connect the gas supply to the appliance.
An olive and nut are provided for
connection to the "T" connector on the
appliance. The connector can be rotated to allow
connection from either side or the rear. The connector
includes a valve for isolating the gas supply.
The closure plate has a cut-out in the base for rear
connection. Seal the gap between the cut-out and the
supply pipe.
Pressure check the installation pipework for gas
soundness. In the United Kingdom check in accordance
with the current edition of BS6891. In the Republic of
Ireland refer to the current edition of IS 813 "Domestic
gas installations".

6.5 Radiants installation.

Important: Fit the radiants ensuring that their rear face rests against the horizontal
ribs in the rear panel. There will be a small gap between their bottom front edges and
the retaining channel at the front of the radiant box.
©