10. GAS SUPPLY CONNECTION

10.1
Fit the gas valve and connector unit to the supply
line.
10.2
Refit the burner unit to the convection box with
three screws.
10.3
Connect the elbow on the gas valve unit to the
burner unit.
10.4
Pressure testing supply line.
Make sure that the gas valve is shut off (control
knob bar at 90° to supply pipe line of flow).
The appliance and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5kPa).
appliance must be isolated from the gas supply
piping system by closing the equipment shut off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig (3.5kPa).
f i r e - p a r t s . c o m
11. CERAMIC WALLS
INSTALLATION
11.1
Fit the ceramic rear wall inside the "L" brackets
on the back face of the burner compartment. Push
the ceramic wall flat against the back face of the
burner compartment (See figure 15).
Fig. 15 Ceramic rear wall installation
11.2
The ceramic side walls can be installed in two
alternative arrangements:
a) With the brick pattern visible - Fit the wall
stamped "A" at the right side and the wall
stamped "B" at the left side.
b) With the plain wall surfaces visible - Fit the
wall stamped "B" at the right side and the wall
stamped "A" at the left side.
Find out which arrangement the customer requires.
Explain that the customer can not alter the wall
arrangement after the front casting is installed.
Fit the ceramic side walls against the side faces of
the burner compartment. The bottom edges of
the walls should rest on the ledges at the sides of
the fire box and the top of the walls should locate
in the space between the black cross member and
the side walls of the burner compartment (See
figure 16).
The
Fig. 16 Ceramic side walls installation
12. FRONT & CONTROL
LINKAGE
12.1
Remove the tape securing the control linking bar to
the casting/surround. Slide the control knob
upwards as far as it will go. This will make sure that
the bottom of the linking bar is higher than the
bottom of the casting/surround when fitting it to
the fireplace
12.2
"Adorn front"; Carefully lift the casting. Do not lift
it by the control knob. Place it against the fireplace
front surface so that the retaining strip at the back of
the casting is above the two upper retaining
brackets at the top of the convection box. Lower the
casting making sure that the rear retaining strip
locates fully over the retaining brackets on the
convection box (See figure 17).
Fig. 17 "Adorn" front casting top location
INSTALLATION
.