Gas Supply Connection; Radiants Installation; Flue Restrictor Adjustment - Valor Regency OXYSAFE 2 Installer's Manual

Table of Contents

Advertisement

positions can alternatively be marked by placing the fire in position and marking the wall
through the holes in the back panel. Drill and plug the holes using no. 10 wall plugs.
Place the fire in position and secure with four no. 10 x 2in. woodscrews.

6.3 Gas Supply Connection

8mm rigid tubing must be used to connect the gas supply to the appliance. An olive and
nut are provided for connection to the "T" connector on the appliance. The connector can
be rotated to allow connection from either side or the rear. The connector includes a
valve for isolating the gas supply.
The closure plate has a cut-out for rear connection. Seal the gap between the cut-out and
the supply pipe.
Pressure check the installation pipework for gas soundness. In the United Kingdom check
in accordance with the current edition of BS6891. In the Republic of Ireland check in
accordance with the rules in force.

6.4 Radiants Installation

Important: Fit the radiants ensuring that their rear face rests against the horizontal ribs
in the rear panel. There will be a small gap between their
bottom front edges and the retaining channel at the front
of the radiant box.

6.5 Flue Restrictor Adjustment

See figure 10.
The appliance has an integral adjustable flue draught
restrictor. This is supplied set in the fully open
(unrestricted) position and in most cases no adjustment
should be necessary. It can be reset to a fully restricted
position if the flue draught is excessive. The restrictor
must remain in its fully open position if the flue has
an equivalent height of 4m or less (as calculated in
accordance with BS5440: Part 1 Appendix A) or
where a pre-cast flue is used.
To close the restrictor:
1. Loosen the screw situated behind the cut-out in the black upper heat shield. Do not
fully remove the screw.
2. Push the restrictor firmly down as far as it will go. The top of the slot in the restrictor
bracket should touch the screw.
3. Fully tighten the screw.
There may be certain exceptional circumstances where closing the restrictor causes the
fire to fail the spillage test (See section 9). In such cases the restrictor will have to be
reopened.
INSTALLER'S GUIDE
Page 15
Figure 10. Flue restrictor
adjustment