Install the PWM Valve Assemblies
Before the PWM valves (P/N 063-0131-140) are mounted on the machine, the proper hydraulic fittings and
mounting brackets must be installed. Refer to the following table to install the fittings in the appropriate ports of
the PWM valve.
Install the PWM Valve Assembly - End Row Units
Using the planter-specific installation guide included in the OmniRow installation kit, identify the number of left
and right end row unit assemblies required for the installation on the machine.
Note:
Examples of end row assembly placement locations are the left and right outside row units of the
planter, and the ends of the center section hydraulic plumbing.
PWM Valve Assembly for End Row Units
FIGURE 9.
Left PWM Valve Assembly
1
4
#
1
Fitting - 9/16" JIC (M) to 9/16" SAE O-Ring (M) 90° Elbow
2
Fitting - 3/4" JIC (M) to 9/16" SAE O-Ring (M) 90° Elbow
3
Fitting - 3/4" JIC M/M/M Bulkhead Tee
4
Fitting - 3/4" JIC (F) Cap
After installing the fittings on the PWM valves as shown above, secure the PWM valves to the mounting
1.
brackets (P/N 107-0171-933) using two 1/4"-20 UNC-2 x 1-3/4" hex head machine bolts (P/N 311-0050-
108) and two 1/4"-20 zinc flanged lock nuts (P/N 312-1001-168) per PWM valve.
Manual No. 016-3001-004
2
1
3
Fitting
Hydraulics
Right PWM Valve Assembly
2
Part Number
Port
333-0012-072
Port 1
333-0012-071
Port 2
Tank Port at
333-0012-314
the End of the
Bracket
Outside Tank
333-0012-272
Tee Branch
4
11