  • Page 1 OmniRow™ Installation Manual John Deere Individual Row Control...
  • Page 2 GPS, GNSS, SBAS, etc.). Therefore, Raven Industries cannot guarantee the accuracy, integrity, continuity, or availability of these services and cannot guarantee the ability to use Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services.
  • Page 3: Table Of Contents

    Disassemble the Planter’s Drive System .................. 6 Install the OmniRow Hydraulic Motors ..................7 Install the Fittings on the OmniRow Hydraulic Motors ............8 Mount the OmniRow Hydraulic Motors ................9 Install the PWM Valve Assemblies ..................11 Install the PWM Valve Assembly - End Row Units ............
  • Page 4 Table of Contents John Deere Individual Row Control OmniRow Installation Manual...
  • Page 5: Important Safety Information

    Raven dealer for support. • Follow all safety labels affixed to the OmniRow system components. Be sure to keep safety labels in good condition and replace any missing or damaged labels. To obtain replacements for missing or damaged safety labels, contact your local Raven dealer.
  • Page 6: Hydraulic Safety

    Chapter 1 WARNING • When starting the machine for the first time after installing OmniRow, be sure that all persons stand clear, in case a hose has not been properly tightened. • Install the enclosed warning labels in a highly-visible area of the planter’s tool bar.
  • Page 7: Chapter 2 Introduction

    Allen wrenches Preparing for Installation Before installing OmniRow, park the machine on a level, clean, and dry surface. Leave the machine turned off for the duration of the installation process. During the installation process, follow good safety practices. Be sure to carefully read the instructions in this manual as you complete the installation process.
  • Page 8: Point Of Reference

    TABLE 1. Dash Size JIC and UNO ORFS 9/16” 1/4” 1/4” 3/8” 3/8” 11/16” 3/8” 3/8” 1/2” 1/2” 13/16” 1/2” 1/2” 5/8” 1” 5/8” 3/4” 3/4” 1-3/16” 3/4” 3/4” 1-7/16” 1” 1” John Deere Individual Row Control OmniRow Installation Manual...
  • Page 9: Hydraulics

    For the OmniRow system to function properly, its hydraulic tank line must connect to a low pressure return connection on the tractor that prohibits the tank pressure from exceeding 200 psi. A motor return connection is the ideal connection for the OmniRow system because it prevents the pressure from being reversed to the system.
  • Page 10: Disassemble The Planter's Drive System

    Remove all sections of the 7/8” hex shaft that drives the row units. Important: Leave the existing sprocket or gearbox on the left side of the row unit. The OmniRow system will utilize it and the existing drive chain or flexible shaft to drive the seed meter.
  • Page 11: Install The Omnirow Hydraulic Motors

    Components to be Removed as Needed FIGURE 4. Remaining jack shafts, transmissions, and/or OEM hydraulic motors can be removed as needed if they interfere with the OmniRow installation. Install the OmniRow Hydraulic Motors WARNING Hydraulics are under pressure. Care should always be taken with a system that has been pressurized.
  • Page 12: Install The Fittings On The Omnirow Hydraulic Motors

    Install the Fittings on the OmniRow Hydraulic Motors Before mounting the OmniRow hydraulic motors on the machine, install the proper fittings in the motors. This prepares the motors for installation and simplifies the hose connection process later in the procedure. Refer to the following table to install the fittings in the appropriate ports of the OmniRow hydraulic motors.
  • Page 13: Mount The Omnirow Hydraulic Motors

    Hydraulics Mount the OmniRow Hydraulic Motors Hydraulic Motor Mounted to the Planter Row Unit FIGURE 6. Parallel Linkage Bars on Inside of Row Unit Motor Installed (Spacer Installed) Mounting Bracket (Spacer Required) Parallel Linkage Bars on Outside of Row Unit...
  • Page 14 Tighten the nuts to secure the motor to the planter row unit. Repeat the steps above to install the hydraulic motors on the remaining planter row units. John Deere Individual Row Control OmniRow Installation Manual...
  • Page 15: Install The Pwm Valve Assemblies

    PWM valve. Install the PWM Valve Assembly - End Row Units Using the planter-specific installation guide included in the OmniRow installation kit, identify the number of left and right end row unit assemblies required for the installation on the machine.
  • Page 16: Install The Pwm Valve Assembly - Middle Row Units

    Fitting - 3/4” JIC M/M to 9/16” SAE O-Ring (M) Branch Tee Adapter 333-0012-315 Port 2 Tank Port at Fitting - 3/4” JIC M/M/M Bulkhead Tee 333-0012-314 the End of the Bracket John Deere Individual Row Control OmniRow Installation Manual...
  • Page 17: Install The Open Center Pressure-Reducing Valve

    Hydraulics After installing the fittings on the PWM valves as shown above, secure the PWM valves to the mounting brackets (P/N 107-0171-933) using two 1/4”-20 UNC-2 x 1-3/4” hex head machine bolts (P/N 311-0050- 108) and two 1/4”-20 zinc flanged lock nuts (P/N 312-1001-168) per assembly. PWM Valve Installed FIGURE 12.
  • Page 18 Ports P, T, and EF should face the planter’s hitch and Ports G1, G2, and T2 should face the planter’s tool bar if possible. John Deere Individual Row Control OmniRow Installation Manual...
  • Page 19: Hydraulic Hose Installation

    Install the 90° end of the supplied hydraulic hose (P/N 214-1000-700) to the fitting installed in the pressure port of the OmniRow hydraulic motor (P/N 413-8000-001) on the first planter row unit. Connect the other end of the supplied hydraulic hose to the fitting installed in Port 1 of the PWM valve (P/N 063-0131-140).
  • Page 20: Install The Planter Row Unit Pressure And Tank Hoses

    FIGURE 16. Pressure Tank Refer to the supplied machine-specific hydraulic installation sheet included with the OmniRow installation kit to install the planter row unit pressure and tank hoses. Important: Pay close attention to the hydraulic hose part numbers on the diagram and the locations in which each must be installed.
  • Page 21 Hydraulics Refer to the supplied machine-specific hydraulic installation sheet included with the OmniRow installation kit to install the open center pressure-reducing valve pressure and tank hoses. Important: Pay close attention to the hydraulic hose part numbers on the diagram and the locations in which each must be installed.
  • Page 22 Chapter 3 John Deere Individual Row Control OmniRow Installation Manual...
  • Page 23: Wiring

    The tractor cables are specific to the tractor being used to pull the planter. For available kits and ordering information, contact your local Raven dealer. Install the chassis cable’s main battery connections, leaving room to provide access to the fuses in the cable.
  • Page 24 Connect the 3-pin metripack connector labeled Row 1 to the motor speed sensor of the hydraulic motor installed on the first row unit. Connect the 2-pin Deutsch connector to the PWM valve installed on the first row unit. John Deere Individual Row Control OmniRow Installation Manual...
  • Page 25 Wiring Seed Tube Sensor Connection FIGURE 4. Connect the remaining 3-pin weatherpack connector to the seed tube sensor on the first row unit. Repeat steps 4 - 6 above to connect the harness cables to the remaining row units. Install the power/CAN extension cable on the remaining receptacle connector on the left harness cable. Extension Cable Routed to the Tractor Hitch FIGURE 5.
  • Page 26: Install The Proximity Switch

    Mount the magnets (P/N 418-0000-013) to the bottom of the node mounting plate using the 1/4”-20 x 3/4” HD hex bolts (P/N 311-0049-103) and 1/4”-20 UNC nylon insert lock nuts (P/N 312-4000-057). John Deere Individual Row Control OmniRow Installation Manual...
  • Page 27 Note: Position the node so that the cable connections face down or to the side. Insert the large, rectangular node connectors on the harness cables into the correct ports of the OmniRow nodes. Tighten the bolts on the node connectors to secure the connections.
  • Page 28 Chapter 4 John Deere Individual Row Control OmniRow Installation Manual...
  • Page 29 Hydraulics Disassembling the Planter’s Drive System 6 Hydraulic Hose Installation 15 Installing the OmniRow Hydraulic Motors 7 Installing the Fittings on the OmniRow Hydraulic Motors 8 Mounting the OmniRow Hydraulic Motors - Newer Models 9 Installing the Open Center Pressure-Reducing Valve 13...
  • Page 30 Index John Deere OmniRow Installation Manual...
  • Page 31 How Can I Get Service? Bring the defective part and proof of purchase to your Raven dealer. If your dealer agrees with the warranty claim, the dealer will send the part and proof of purchase to their distributor or to Raven Industries for final approval.
  • Page 32 P.O. Box 5107 Fax: 605-331-0426 Sioux Falls, SD 57117-5107 www.ravenprecision.com Notice: This document and the information provided are the property of Raven Industries, Inc. and may only be used as authorized by Raven Industries, Inc. All rights reserved under copyright laws.