Nozzle control system for et apache as 720, 730, 1020, 1025, 1030, 1220, and 1230 series (48 pages)
Summary of Contents for Raven OmniRow
Page 1
OmniRow™ Installation Manual White MultiRow...
Page 2
GPS, GNSS, SBAS, etc.). Therefore, Raven Industries cannot guarantee the accuracy, integrity, continuity, or availability of these services and cannot guarantee the ability to use Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services.
Install the OmniRow Hydraulic Motors ..................8 Install the Fittings on the PWM Valve .................. 8 Install the PWM Valve and Fittings on the OmniRow Hydraulic Motor ......10 Install the Drive Couplers ....................10 Mount the OmniRow Hydraulic Motors ................11 Install the Pressure Gauge Test Kit ..................
Page 4
Table of Contents White MultiRow OmniRow™ Installation Manual...
Raven dealer for support. • Follow all safety labels affixed to the OmniRow system components. Be sure to keep all safety labels in good condition and replace any missing or damaged labels. To obtain replacements for missing or damaged safety labels, contact your local Raven dealer for support.
Chapter 1 WARNING • When starting the machine for the first time after installing OmniRow, be sure that all persons stand clear, in case a hose has not been properly tightened. • Install the enclosed warning labels in a highly-visible area of the planter’s tool bar.
Recommendations Raven Industries recommends the following best practices before installing or operating the OmniRow system for the first time, at the start of the season, or when moving the OmniRow system to another machine: • Ensure the machine’s hydraulic filters have been recently changed and there are no issues with the machine’s hydraulic system (e.g., pump issues, faulty hydraulic motors, fine metal deposits in the hydraulic...
Chapter 2 Tools Needed The following tools are recommended for installation of the OmniRow system: • SAE standard-sized wrenches/sockets • Metric wrenches/sockets • Allen wrenches • Cable ties • Set of tools Point of Reference The instructions in this manual assume that you are standing behind the planter, looking toward the planter’s hitch or tractor.
For the OmniRow system to function properly, its hydraulic tank line must connect to a low pressure return connection on the tractor that prohibits the tank pressure from exceeding 200 psi. A motor return connection is the ideal connection for the OmniRow system because it prevents the pressure from being reversed to the system.
Important: Leave the existing sprocket on the right side of the row unit. The OmniRow system will utilize it and the existing drive chain to drive the seed meter.
Page 11
FIGURE 3. Supplemental support bearings (from the left side of the planter row units, opposite the seed meter drive sprocket) can be removed as needed if they interfere with the OmniRow installation. Important: Supplemental support bearings may be required to help support section shafts. Refer to the supplied installation guide to determine if and where support bearings need to be placed.
Chapter 3 Remaining jack shafts, transmissions, and/or OEM hydraulic motors can be removed as needed if they interfere with the OmniRow installation. Install the OmniRow Hydraulic Motors Install the Fittings on the PWM Valve End Row Units Fittings and PWM Valves Installed - End Row Units FIGURE 5.
Page 13
Hydraulic System Installation Middle Row Units Fittings Installed PWM Valve - Middle Row Units FIGURE 6. P/N 333-0012-064 P/N 333-0012-315 P/N 333-0012-240 Fitting Part Number Port Fitting - 9/16” SAE O-Ring (M) to 9/16” SAE O-Ring (M) Straight Adapter 333-0012-240 Fitting - 3/4”...
P/N 333-0012-039 P/N 333-0012-093 Install the PWM valve assembly in the pressure port of the OmniRow hydraulic motor (P/N 416-8000-001). Install a 3/4” SAE O-ring (M) to 3/4” JIC (M) straight adapter fitting (P/N 333-0012-093) in the tank port of the OmniRow hydraulic motor.
Figure 10 below: Drive Coupler Assembly - Motor Tied on Both Sides FIGURE 10. Mount the OmniRow Hydraulic Motors Important: Ensure the motor, mounting bracket, and hardware do not come into contact with the parallel linkage bars or row cleaner/coulter attachments when the row unit travels up and down.
Page 16
Secure the hex shafts with existing shaft collars, supplied hex collars (P/N 107-0172-082), and/or cotter pins on the opposite side of the existing bearing or sprocket that is not next to an OmniRow hydraulic motor. White MultiRow OmniRow™ Installation Manual...
Page 17
Hydraulic System Installation Insert the supplied cotter pin (P/N 312-0000-395) in the hex coupler to secure the installed shafts. Secure any wires within close proximity of the installed hydraulic motor to prevent interference with the operation of the row unit. Note: Do not secure the wires between the motor and the row unit mounting bracket, as this makes it difficult to access the wires if maintenance is required.
Secure the hex shafts with existing shaft collars, supplied hex collars (P/N 107-0172-082), and/or cotter pins on the opposite side of the existing bearing or sprocket that is not next to an OmniRow hydraulic motor. Insert the supplied cotter pin (P/N 312-0000-395) in the hex coupler to secure the installed shafts.
Install the Fittings on the Valve Before mounting the OmniRow hydraulic valve on the machine, install the proper fittings in the valve. This prepares the valve for installation and simplifies the hose connection process later in the procedure. Refer to the following table to install the fittings in the appropriate ports of the OmniRow valve.
P/N 107-0171-956 Note: The OmniRow hydraulic valve should be mounted at the front of the planter, near the hitch in a location that allows the hydraulic hoses to be connected to it without interference. Refer to the machine-specific hydraulic installation sheet for the location. Ports P, T, and EF should face the planter’s hitch and Ports G1, G2, and T2 should face the planter’s tool bar if possible.
Page 22
End Row Unit Assembly Install 90° hose ends on the fittings pointing up Install straight hose ends on the fittings on 90° elbow fittings 90° hose ends installed Straight hose ends installed on 90° elbow fitting White MultiRow OmniRow™ Installation Manual...
Page 23
Hydraulic System Installation Pressure and Tank Hoses Installed FIGURE 20. Left End Configuration Right End Configuration Tank Pressure Left Middle Configuration Right Middle Configuration Tank Pressure Install the supplied hydraulic hoses on each end of the installed tee fittings in Port 2 of the PWM valves, continuing from one section to the next, until all pressure hoses are installed.
Install the supplied hydraulic hose labeled P on the fitting installed in Port P of the OmniRow valve. Install the supplied hydraulic hose labeled T on the fitting installed in Port T of the OmniRow valve.
Hydraulic System Installation Install the supplied hydraulic hose labeled EF on the fitting installed in Port EF of the OmniRow valve. Note: If the hydraulic system will be configured as a closed center system, do not install the EF hose in Port EF of the OmniRow valve.
Pressure (Labeled ‘P’) Tank (Labeled ‘T’) Connect the pressure hose (labeled ‘P’) to the pressure side of the tractor’s SCV. Connect the tank hose (labeled ‘T’) to the low pressure motor return on the tractor. White MultiRow OmniRow™ Installation Manual...
The tractor cables are specific to the tractor being used to pull the planter. For available kits and ordering information, contact your local Raven dealer. Install the chassis cable’s main battery connections, leaving room to provide access to the fuses in the cable.
Chapter 4 Install the OmniRow Harness Cables Note: On planters equipped with 24 planter row units, the harness cable is divided in half. The left harness cable and right harness cable connect together at the middle of the planter. Locate the cable connectors on each harness cable to determine which ends of the harness cables are installed on the end row units of the planter.
Wiring Installation Seed Tube Sensor Connection FIGURE 3. Connect the remaining 3-pin weatherpack connector to the installed seed tube sensor on the first row unit. Repeat steps 4 - 6 above to connect the harness cables to the remaining row units. Install the power/CAN extension cable on the remaining receptacle connector on the left harness cable.
Note: Position the node so that the cable connections face down or to the side. Insert the large, rectangular node connectors on the harness cables into the correct ports of the OmniRow node(s). Tighten the bolts on the node connectors to secure the connections.
Page 31
• Hydraulic fluid is not leaking from the system. Cycle the planter up and down functions to verify there is no interference with the installed OmniRow system. If the planter is equipped with row cleaners/coulters, verify travel or row cleaners/coulters do not interfere with OmniRow equipment and make necessary routing changes to prevent contact.
Page 32
Chapter 4 White MultiRow OmniRow™ Installation Manual...
Page 33
Installing the OmniRow Hydraulic Valve 15 Installing Fittings on the Valve 15 Mounting the OmniRow Hydraulic Valve 16 Installing the OmniRow Hydraulic Valve Pressure and Tank Hoses 20 Installing the Pressure and Tank Hoses 17 Installing the Pressure Gauge Test Kit 14...
Page 34
Index White MultiRow OmniRow™ Installation Manual...
Page 35
How Can I Get Service? Bring the defective part and proof of purchase to your Raven dealer. If your dealer agrees with the warranty claim, the dealer will send the part and proof of purchase to their distributor or to Raven Industries for final approval.
Page 36
Outside the U.S. :1 605-575-0722 Sioux Falls, SD 57117-5107 Fax: 605-331-0426 www.ravenprecision.com www.ravenhelp.com Notice: This document and the information provided are the property of Raven Industries, Inc. and may only be used as authorized by Raven Industries, Inc. All rights reserved under copyright laws.