Raven SideKick Pro Installation & Operation Manual

Raven SideKick Pro Installation & Operation Manual

Icd 1-40 oz./min. and 5-200 oz./min.
Table of Contents

Advertisement

Quick Links

SideKick Pro™ ICD 1-40
oz./min. and 5-200 oz./
min. Installation &
Operation Manual
016-0171-605 Rev. E
1/2020
E34591
Copyright 2020

Advertisement

Table of Contents
loading

Summary of Contents for Raven SideKick Pro

  • Page 1 SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./ min. Installation & Operation Manual 016-0171-605 Rev. E 1/2020 E34591 Copyright 2020...
  • Page 2 Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services. Raven Industries accepts no responsibility for the use of any of these signals or services for other than the stated purpose.
  • Page 3: Table Of Contents

    ............................16 Initial Plumbing and Point of Injection ......................16 Best Practices ..................................16 Mount the Sidekick Pro™ ICD Pump and Chemical Tank ................. 21 Mount the Injection Module ............................21 Mount the Chemical Tank ..............................22 Mount the Sidekick Pro ICD Pump ..........................23...
  • Page 4 Motor Control ECU LED Status Indicators .......................55 Diagnostic Trouble Codes (DTCs) ........................56 Injection Pump Troubleshooting Steps (If Pump Does Not Calibrate) ..........58 Required Tools ..................................58 Troubleshooting Procedure .............................58 SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 5: Important Information

    • Do not operate this Raven system or any agricultural equipment while under the influence of alcohol or an illegal substance. • Be alert and aware of surroundings and remain in the operator’s seat at all times when operating this Raven system.
  • Page 6: Agricultural Chemical Safety

    • Stand clear of the implement when starting the system for the first time after installing or servicing hydraulic components in case a hose has not been properly connected or tightened. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 7: Electrical Safety

    • Do not connect the power leads to the battery until all system components are mounted and all electrical connections are completed. • Always start the machine before initializing this Raven system to prevent power surges or peak voltage. • To avoid tripping and entanglement hazards, route cables and harnesses away from walkways, steps, grab bars, and other areas used by the operator or service personnel when operating or servicing the equipment.
  • Page 8: Wire Routing

    • Clean electrical components with pressurized air, aerosol electrical cleaning agent, or low pressure rinse. • Remove visible surface water from electrical components and connections using pressurized air or an aerosol cleaning agent. Allow components to dry thoroughly before reconnecting cables. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 9: Introduction

    C H A P T E R 3 SYSTEM OVERVIEW The Raven Sidekick Pro™ ICD (ISO Client Device) Direct Injection system is designed to provide efficient and accurate application of liquid chemicals from an injection module. By using a separate injection module, the system eliminates mixing chemicals in the tank, reduces chemical waste, and simplifies equipment care and maintenance.
  • Page 10: Injection System Components

    • Cabling required to connect injection system components and existing ISOBUS The following ISOBUS control consoles may be used with the injection system: • Viper 4 • CR7 or CR12 • ISOBUS compatible UT SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 11: Sidekick Pro™ Icd Features

    RINSE ASSIST The Sidekick Pro™ Rinse Assist provides a quick method to rinse the injection pump with clean water which helps to ensure problem-free operation of the Sidekick Pro injection system. The Rinse Assist system utilizes an automated 3-way rinse valve to switch the inlet source to a rinse tank without leaving the cab.
  • Page 12: Fast Rate Response

    Sidekick Pro™ ICD injection pump. This feature allows the operator to run multiple calibration tests quickly and easily and ensure the system is ready for operation.
  • Page 13: System Diagnostics

    • Perform a catch test • Rinse the pump SYSTEM DIAGNOSTICS Enhanced diagnostic features are monitored by the UT during operation of the Sidekick Pro™ ICD injection system to help identify potential issues and minimize equipment down time. FLOW MONITORING The Sidekick Pro™...
  • Page 14 Inlet and Outlet Plumbing Mates with Banjo M100 Flange and 3/4” Female NPT Wetted Parts Polypropylene Stainless Steel Body Material Polypropylene Wetted Seals/O-rings Type GF Viton and Graphite Filled Teflon SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 15 INTRODUCTION FIGURE 5. Sidekick Pro ICD Injection Pump Dimensions Sidekick Pro™ ICD Injection Pump Dimensions TABLE 2. English Metric Dimension (in.) (cm) 20.1 24.4 20.8 10.9 9.25 23.5 16.5 41.91 12.96 32.92 NOTE: 1-40 oz./min. pump shown. Overall length of the 5-200 oz./min. pump is 16.19 inches [41.12 cm].
  • Page 16: Updates

    Updates for Raven manuals as well as several system components are available at: portal.ravenprecision.com Sign up for e-mail alerts to receive notice when updates for your Raven products are available on the Raven web site. At Raven Industries, we strive to make your experience with our products as rewarding as possible.
  • Page 17: Installation

    See the Mount the Sidekick Pro™ ICD Pump and Chemical Tank section on page 21. 4. Plumb the Sidekick Pro™ ICD pump and injection lines into the main carrier line at point of injection. See the Sidekick Pro™ ICD Injection System Plumbing section on page 24.
  • Page 18: Tank Agitator Installation

    BEST PRACTICES • The Raven Sidekick Pro™ ICD injection system pumps chemical into the main carrier line at the point of injection. This point must be on the pressure side of the carrier product pump and should be as close to the boom section valves as possible.
  • Page 19 INSTALLATION To set up the point of injection: 1. Select the point of injection. 2. Install a carrier check valve or a mixer assembly in the main product line to prevent back flow to the carrier reservoir. Refer to Table 2 on page 18 for assistance with proper sizing of the carrier check valve or see Figure 4 on page 19 for details on available mixer assemblies.
  • Page 20 “102” Identifier. Rated for 12 PSI [82.7 kPa] (cracking pressure). Stainless steel for NH3 applications. Verify the check valve is installed with the flow arrow pointing in the direction of flow through the valve. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 21 INSTALLATION FIGURE 4. In-Line Mixer Selection Chart (P/N 063-0171-303) (P/N 063-0159-632) (P/N 063-0171-300) (P/N 333-9000-010) (P/N 063-0173-770) (P/N 063-0173-737) (P/N 063-0173-698) (P/N 063-0173-699) Installation: Initial Plumbing and Point of Injection...
  • Page 22 1. 2” Check Valve and 2” Poly Mixer 2. 3” Check Valve and 3” Mixer 3. 1.5” NPT NH Mixer (Without Check Valve) 4. 4” Check Valve and 4” Mixer SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 23: Mount The Sidekick Pro™ Icd Pump And Chemical Tank

    MOUNT THE SIDEKICK PRO™ ICD PUMP AND CHEMICAL TANK Installation and mounting of the Sidekick Pro™ ICD injection pump and injection module, or chemical tank, will vary between implements. Use the following sections to help select an appropriate mounting location on the implement.
  • Page 24: Mount The Chemical Tank

    Increase the tubing diameter • Mount the Sidekick Pro™ ICD pump so that the line between the injection pump and chemical supply tank is near level with a slight incline to help relieve air bubbles. The line connected to the pump inlet must not raise chemical more than 2 ft.
  • Page 25: Mount The Sidekick Pro Icd Pump

    • Mount the Sidekick Pro™ ICD pump as close as possible to the selected point of injection. • Mount the Sidekick Pro™ ICD pump so that the outlet port is pointing up. The pump will not meter product application correctly if the pump is mounted in any other orientation.
  • Page 26: Sidekick Pro™ Icd Injection System Plumbing

    Connect the pump outlet to the injection check valve at the point of injection. Use the following hose sizes depending upon the capacity of the injection pump used with the system. Pump Capacity Tubing Size 1-40 oz./min. 3/8” 5-200 oz./min. 1/2” SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 27: Plumb The Sidekick Pro™ Icd Closed Calibration System

    The Sidekick Pro injection system includes the pump calibrator, a 3-way ball valve, and vented check valve which allows the system to detect whether the pump is primed and also allows for recirculation of chemical back to the chemical supply tank.
  • Page 28: Plumb The Rinse Assist System

    Before installing the Rinse Assist system, review the following components provided with the Rinse Assist kit. Contact a local Raven dealer for questions or additional assistance with these components: FIGURE 10. Low Profile Sidekick Pro Rinse Assist Kit (P/N 117-0171-773 Rev. B) To Chemical Tank...
  • Page 29: Plumbing The Rinse Assist 3-Way Valve To The Injection Pump

    FIGURE 11. Rinse Assist 3-Way Valve Plumbing NOTE: Install the 100 flanged fitting (item 10) between the pump and M100 flange gasket (item 6) when clearance is needed for the flow monitor sensor. Installation: Sidekick Pro™ ICD Injection System Plumbing...
  • Page 30: Isobus And Power Connections

    ISOBUS AND POWER CONNECTIONS The Sidekick Pro™ ICD connects to an ISOBUS system via an integrated motor control ECU. The injection pump requires a connection to both clean logic power and high current power either at the battery or a power bus bar.
  • Page 31: Best Practices

    5. Use dedicated bus bars to connect the console and all nodes to the same source for both power and ground. 6. Provide relays to switch power on and off to avoid draining the battery. Raven recommends connecting the console to a clean power source (at relay) and using the console ‘orange’ wire to activate the relay. This makes the console the master power switch and allows engine shutdown without turning off the console.
  • Page 32: Verifying Installation Of The Sidekick Pro™ Icd

    5. Check for any leaks at each plumbing connection before applying chemicals with the injection system. It is also recommended to check the system periodically and replace worn or damaged connections, valves, or hoses. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 33: Calibration And Operation

    To access the calibration and diagnostics for a specific injection product: Sidekick Pro Home ICD Menu 1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu button. 2. Press the Home icon. The following information will display: Calibration and Operation: Flow Monitor Sensor...
  • Page 34: System Settings

    System Settings ICD Menu Setup 1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu button. 2. Press the Product Setup button. 3. Select Settings. The following information will display: SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 35: Rate Settings

    Product Rate Settings ICD Menu Setup 1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu button. 2. Press the Product Setup button. 3. Select the Rate Settings tab. The following information will display: NOTE: The following Rate Settings options will only be displayed when connected to a rate per area device.
  • Page 36: Alarms Settings

    ALARMS SETTINGS Sidekick Pro Product System Settings ICD Menu Setup 1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu icon. 2. Select Alarms Settings. The following information will display: Alarms Information TABLE 4. Alarms Description The minimum allowable efficiency for the DI pump. Typical values range from 60 - 99%.
  • Page 37: Current Totals Data

    Sidekick Pro Totals Current Totals ICD Menu Data 1. Open the UT Menu and select the desired Sidekick Pro™ ICD menu icon. 2. Select the Totals Data icon then Current Totals. The following information will display: Current Totals TABLE 5. Display...
  • Page 38: System Information

    Diagnostics Product ICD Menu Information 1. Open the UT Menu and select the desired Sidekick Pro™ ICD Menu icon. 2. Select the Diagnostics icon. 3. Select Product Information. 4. Select the desired information from the drop-down. The options are: •...
  • Page 39: Tests

    Also, verify that the product is flowing freely. Cold temperatures and high viscosity products may cause high vacuum pressures and cause the pump to not operate properly. 4. Select the Sidekick Pro™ ICD Menu icon. 5. Select Diagnostics. 6. Select Test.
  • Page 40: Pump Calibration With Pump Calibrator

    Also, verify that the product is flowing freely. Cold temperatures and low viscosity products may cause high vacuum pressures and cause the pump not to operate properly. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 41 CALIBRATION AND OPERATION FIGURE 3. Vacuum Switch 6. Touch the Sidekick Pro ICD Menu button. FIGURE 4. Sidekick Pro ICD Menu Button Sidekick Pro Diagnostics Test ICD Menu 7. Select the Diagnostics tab. 8. Select Test. 9. Use the drop down Select the Pump Calibration Test.
  • Page 42: Catch Test

    3. Disconnect the coupler from the top of the chemical tank and place the recirculation hose in the catch test vessel. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 43: Demonstration Mode

    If the problem persists, refer to the Chapter 7, Troubleshooting, for assistance. DEMONSTRATION MODE Use Demonstration Mode to simulate pressure with a specified value and to stimulate flow. To operate the Sidekick Pro™ ICD in demonstration mode: 1. Select the Diagnostics icon. 2. Select Test.
  • Page 44: Diagnostic Trouble Codes

    VIEW INACTIVE DTCS Shows the SPN and FMI for all of the inactive DTCs along with a short description and the number of times the error occurred. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 45: System Maintenance

    Perform these maintenance procedures periodically over a season and be sure to store the pump properly when not being used. Depending upon the type of chemicals used with the Raven injection system, periodic maintenance may be required to ensure proper operation of the injection pump.
  • Page 46: Check Valve Maintenance

    2. Carefully remove the intake and discharge valve cartridges from the injection pump using a 9/16” Allen wrench or a 1-1/4” box end wrench for valves equipped with sensors. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 47 3. Examine the valve assembly O-ring and replace if cut or nicked. These O-rings are made of a chemical resistant compound and should only be replaced with O-rings supplied by a local Raven dealer. 4. Disassemble the check valve assemblies as shown in Figure 2 below.
  • Page 48 Valve, Body Intake 106-0159-622 219-0002-018 O-ring (Viton) 219-0002-018 a. Plug fitting (P/N 107-0171-955) is used with check valve assemblies (P/N 063-0173-310). b. O-rings included in Pump Seal Kit (P/N 117-0171-657). SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 49: Pump Cam And Bearing

    New piston seals are supplied in the Pump Seal Kit (P/N 117-0171-657, see Table 2 on page 49) available through a local Raven dealer. Complete replacement kits (P/N 063-0172-924) for both 1-40 Oz./min. and 5-200 Oz./min. pumps are available through a local Raven dealer.
  • Page 50 FIGURE 5. Pump Head Parts and Seal Installation White Valve White Valve Piston (4 Places) Bearing (2 Places) 4 Piston (2 Places) Torque to 41 in/lbs. (17 places) (2 Places) Blue Valve Blue Valve SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 51 O-rings used with the piston. The seals and O-rings are made of a chemical resistant compound and should only be replaced with O-rings supplied by a local Raven dealer. 7. Remove the piston from the pump.
  • Page 52: Injection Pump Pressure Transducer

    To replace the pressure transducer (P/N 422-0000-090): 1. Disable and shutdown any automatic product control features of the Sidekick Pro injection system and turn off the vehicle when replacing the pressure transducer assembly. WARNING Hazardous chemicals may be under pressure even if the pump has not been in service recently.
  • Page 53: Injection Pump Vacuum Switch

    To replace the vacuum switch (P/N 063-0171-035): 1. Disable and shutdown any automatic product control features of the Sidekick Pro injection system and turn off the vehicle when replacing the vacuum switch assembly. WARNING Hazardous chemicals may be under pressure even if the pump has not been in service recently.
  • Page 54: Flow Monitor Sensor

    3. Loosen the sensor bracket mounting screws enough to allow the bracket to slide freely on the pump head. ADJUSTING THE STANDARD FLOW MONITOR SENSOR AND BRACKET Pump Flow Monitor Sensor SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 55: Returning The Pump For Service Or Repair

    Refer to the following procedure should it be necessary to return the Sidekick Pro ICD injection pump for service or repairs: 1. Prior to disconnecting the injection pump, drain the chemical tank and rinse with clean water.
  • Page 56 CHAPTER 6 SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 57: Troubleshooting

    C H A P T E R 7 MOTOR CONTROL ECU LED STATUS INDICATORS The Sidekick Pro ICD integrated motor control ECU displays the status of the injection pump with the following ECU status indicators. FIGURE 1. LED Status Indicators...
  • Page 58: Diagnostic Trouble Codes (Dtcs)

    3. Verify speed sensor and signal. Refer to 523169 Low motor voltage the field computer operation manual for information on testing speed and flow cabling and troubleshooting the speed sensor. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 59 There may be debris in the inlet, a plugged filter/strainer, hand valve turned the wrong directions or obstruction in the outlet of the chemical tank. Return pump to a local Raven dealer for Injection pump fault service. 523189 Invalid pump calibration Adjust the flow correction offset.
  • Page 60: Injection Pump Troubleshooting Steps (If Pump Does Not Calibrate)

    The inlet plumbing size on the 1 - 40 oz./min pump should be 1/2” ID minimum. Inlet for the 5 -200 oz./min pump should be 3/4” ID minimum. SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 61 Troubleshooting Alarms Motor Control Node LED Status Indicators Features Closed Calibration System Integrated Motor Control Node System Diagnostics Verifying Installation of the Sidekick Pro Installation Chemical Tank Initial Plumbing and Point of Injection Injection Module Overview Sidekick Pro Pump Verifying Sidekick Pro...
  • Page 62 Index SideKick Pro™ ICD 1-40 oz./min. and 5-200 oz./min. Installation & Operation Manual...
  • Page 63 Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility.
  • Page 64 Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility.

Table of Contents