PGV...-F200/-F200A...-R4-V19
Product Description
2.2

The RS-485 Interface

The read head is equipped with an RS-485 interface for communication purposes, i.e., param-
eterizing the read head functions or reading out current process data during operation. This
interface is operated in 8-E-1 mode and fitted with a terminator that can be activated or deacti-
vated by parameterizing the sensor head accordingly. The RS-485 interface supports the fol-
lowing transfer rates:
38400 bit/s
57600 bit/s
76800 bit/s
115200 bit/s (preset value)
230400 bit/s
Data structure of the RS-485 interface
Bit 0
Bit 1
Bit 2
Start
LSB
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Parity
MSB
Stop
9