The Code Cards "Cancel", "Use", And "Default - Pepperl+Fuchs PGV F200A R4-V19 Series Manual

Incident light positioning system
Hide thumbs Also See for PGV F200A R4-V19 Series:
Table of Contents

Advertisement

PGV...-F200/-F200A...-R4-V19
Commissioning
Note
Press button 2 briefly to exit parameterization mode. Any parameter changes that are made but
have not yet been saved are discarded. The reader then operates with the last valid parameters
that were saved.
4.3.2.1

The code cards "CANCEL", "USE", and "DEFAULT"

Holding one of these cards in front of the reading head exits parameterization mode with the
following consequences:
CANCEL:
All parameter changes that are made but have not yet been saved are discarded. The
reading head operates with the last valid parameters that were saved.
USE:
For test purposes, the reading head operates with the parameters that have just been
modified. The parameterization is not saved, however. After being switched off and on
again, the reading head operates with the last valid parameters that were saved.
DEFAULT:
All parameters in the reading head are overwritten with the original default settings. Re-
enter the configuration mode and save the default settings nonvolatile with the code card
STORE.