IUH-F192-V1-*
Commissioning
4.3

Operation via the Command Interface

This section shows you how to operate the read/write head using an IDENTControl control
interface with serial interface. The commissioning procedure described relates to the RS-232
interface and involves a PC. The examples include the syntax for coding the commands and
parameters via the Ethernet TCP/IP and PROFIBUS/PROFINET interfaces. Further details
about these codes and the factory settings for your IDENTControl control interface can be
found in the manual.
Example:
In the examples below, the read/write head is connected to channel 1 of the control interface.
The outputs follow the multiframe protocol, .
Reading the Country Identifier
Read Parameter RC
Use the read parameter RC command to read out the read/write head's country identifier:
Command:
Confirmation:
Response:
Table 4.1
The country identifier set on the read/write head is 01, where 01 corresponds to the country
identifier for the European Union.
Writing the Country Identifier
Write Parameter RC
Use the write parameter RC command to change the country identifier on the read/write head
to 04 (= India).
Command:
Confirmation:
Response:
Table 4.2
Reading Tags
Enhanced Read Read-Only Code
Send the enhanced read read-only code command to the read/write head. The "RF ON" LED
on the read/write head lights up blue.
Command:
Confirmation:
Response:
Table 4.3
Serial
Ethernet
RP1URC.00.00
.00.0A.BE.03.00.55.52.43.
00.00
-
.00.06.BE.03.FF.3E
.30.31.00.01
.00.0A.BE.03.00.3F.00.02.
00.01
Read Parameter RC
Serial
Ethernet
WP1URC.00.02.
.00.0C.BF.03.00.55.52.43.
00.04
00.02.00.04
-
.00.06.BF.03.FF.11
.30.31
.00.06.BF.03.00.12
Write Parameter RC
Serial
Ethernet
EF1
.00.04.1D.03
-
.00.06.1D.03.FF.0B
.35.31
.00.06.1D.03.05.0C
Enhanced read read-only code, no tag in the measurement range
PROFIBUS/PROFINET
.BE.03.00.55.52.43.00.00
.BE.03.FF.3E
.BE.03.00.3F.00.02.00.01
PROFIBUS/PROFINET
.BF.03.00.55.52.43.00.02.
00.04
.BF.03.FF.11
.BF.03.00.12
PROFIBUS/PROFINET
.1D.03
.1D.03.FF.0B
.1D.03.05.0C