PGV...-F200/-F200A...-R4-V19
Operation and communication
5.1.2.2

Orientation O

The orientation O indicates the orientation of the control codes in the reading window.
Meaning of Bits
O1
O0
0
0
0
1
1
0
1
1
Orientation
O1=0
O0=0
Figure 5.1
Meaning
Control code has the same orientation as ascending Data Matrix lane
Orientation of control code rotated 90° clockwise in relation to ascending Data
Matrix lane
Orientation of control code rotated 180° clockwise in relation to ascending Data
Matrix lane
Orientation of control code rotated 270° clockwise in relation to ascending Data
Matrix lane
O1=1
O0=0
O1=0
O0=1
X
Y
O1=1
O0=1