Pepperl+Fuchs PGV F200A R4-V19 Series Manual page 27

Incident light positioning system
Hide thumbs Also See for PGV F200A R4-V19 Series:
Table of Contents

Advertisement

PGV...-F200/-F200A...-R4-V19
Installation
Caution!
Alignment
The Data Matrix code is not on the center line of the code tape.
The code tape is made of silicone-free polyester film. A position marker appears every 100 mm
along the lower edge of the code tape (see "Code Tape Dimensions"). This position marker is
used for various functions, including precise positioning of the code tape during installation.
The reverse side of the code tape carries a permanent modified acrylate-based adhesive. Affix
the self-adhesive code tape along the desired travel path. To do so, proceed as follows:
Installing the Code Tape
1.
Clean the surface of any greasy or oily deposits and dust.
2.
Ensure that the surface is dry, clean, and stable.
3.
Pull away a few centimeters of the protective film at the beginning of the code tape. Place the
code tape at the precise point of the required starting position on the surface, and press to
attach.
4.
Then affix the code tape along the desired travel path. Remove the protective film gradually so
that the code tape does not accidentally adhere to the surface in the incorrect position. When
affixing, ensure that the code tape does not crease or trap air bubbles.
The adhesive on the code tape hardens after 72 hours.
Note
Thermal Expansion of the Code Tape
The affixed code tape corresponds to the heat expansion coefficient of the surface with regard
to its thermal expansion.
Code Tape Dimensions
Figure 3.21
Position the code tape so that the www.pepperl-fuchs.com label and the position markings
are to the right of the Data Matrix code in the X direction. The position values then increase
along the X direction.
The center line indicates the center of the code tape and not the center of the code
27

Advertisement

Table of Contents
loading

Table of Contents