GigE Line Scan Camera User Manual
Figure 7-26 Set Trigger Cache in Frame Trigger
If the device receives the 1st trigger signal first, and the device receives the 2nd trigger
signal during processing the 1st trigger signal.
● Disable Trigger Cache Enable: the 2nd trigger signal will be filtered without processing.
Figure 7-27 Second Frame Filtered
● Enable Trigger Cache Enable: the 2nd trigger signal will be saved.
If the 1st frame image's exposure time of the 2nd trigger signal is not earlier than the
device's last frame creation time of the 1st trigger signal, and then the 2nd trigger signal's
1st frame image is created normally.
Figure 7-28 Second Frame Created Normally
33