6.11. TEXT MESSAGES CONFIGURATION

In order for installer to be able to configure text messages, administrator has to grant him
necessary permission first. This can be achieved by typing in following code:
<administrator code>
Next, installer's access to text messages can be changed by pressing the
toggle led 1. When the led is active, installer is granted the access, when led is inactive,
installer is refused access to text messages. Choice of installer's permissions can be
accepted by pressing the
CPX200N can store up to 10 phone numbers and up to 32 text messages. If, for any reason,
the SMS can not be send at the moment, it will be send as soon as the connection with the
GSM network is re-established but not later than 1 day after the occurrence of the event
triggering SMS send request (text messages get expired and are deleted). Message should
contain only characters from English alphabet. Furthermore, if the text contains any spaces,
content of the message, starting from the equation mark (=) till the end of the message,
should be enclosed in quotes (" ").
Intaller can configure the text messages using following commands:
Command syntax
Command description
Feedback message
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
button.
Acquiring the state of partitions
XXXX GETARMED
Acquiring the information which partitions are
armed/disarmed
XXXX – user code
Example: 1234 GETARMED
PARTITION1:X, PARTITION2:Y
or
GETARMED:ERROR
.
key. This will
34 / 106