EBS CPX200N Installation And Programming Manual page 91

Alarm control unit
Table of Contents

Advertisement

10.1.3.2. CPGETUSERID
Format:
Limitations:
Description
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
CPGETUSERID=password
This command only works when sent through an encrypted way and the
option "Allow remote user management" is set to active in the
Configurator. Possible to execution only by ATS
Verifies the user code specified as an argument of the command - checks
whether a user with the specified code exists.
Password is the password of the user, id is the user number, partitions
are the partitions to which the user is authorized - bit 0 corresponds to
the partition 1 , bit 1 to the patition 2. The command returns:
CPGETUSERID:EOK,id,partitions
If the user with the specified code exists
CPGETUSERID:EPERMISIONS
If the specified password is incorrect
CPGETUSERID:ENOT_ALLOWED
If the command is sent via open SMS or the configuration does not allow
remote management of users
CPGETUSERID:EFORMAT
If the format of the sent command is incorrect