You can press

6.6. SYSTEM OPTIONS

That function allow to switch on and switch off additional options of the system. The
argument of the function is BIT type. By pressing 1, 2 and 3 keys, you can switch on/off
proper option. 3 beeps will confirm the successfully entered function.
Where:
Options – number of option (BIT type parameter):
 1 – enable faults memory indication – when is switched off, LED SYSTEM does not
show by blinking the faults that are not active; you can display inactive faults by
choosing "faults memory" user function
 2 – disable ATS monitoring. If his option is enabled, ATS failure isn't signaled to the
user in any way on the keypad and it doesn't cause arm prevention.
 3 – disable automatic arm prevention overriding when fault. If this option is disabled
and at least on fault is active in the system, arm prevention isn't signaled to the user
during partition arming. Instead arm prevention is automatically overridden. If option
is enabled, faults causes arm prevention which can be overridden by user.
You can press

6.7. USERS REMOTE MANAGEMENT

That function allow to switch on or switch off remote users management. The argument of
the function is BIT type. By pressing key 1, you can switch on/off option. 3 beeps will
confirm the successfully entered function.
Where:
Options – number of option (BIT type parameter):
 1 – Users remote management enable – when is swiched on
You can press

6.8. ZONES CONFIGURATION

Zones can be configured using complex service functions, after activation of which, all the
parameters related to the relevant zone can be given subsequently or in a form of series of
service functions that configure one zone-related parameter. Addresses of zone
configuration functions are defined as per the following pattern:
where:
XX –
determines the number of zone from 01 to 07; entering number 00 will change the
parameters for all zones in the system,
Y
– number of parameter related to a given zone:
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
any time to exit without saving changes.
any time to exit without saving changes.
any time to exit without saving changes.
<XX> <Y>
<Options>
<Options>
29 / 106