4. ALARM CONTROL UNIT CONFIGURATION

4.1. ZONE BLOCKING

The zone blocking function allows de-activating stand-by mode of any zones or bypassing
any damaged lines. Also, zones which are not in stand-by mode and which the user has
access to can be blocked. Zones remain blocked until de-arming. System informs the user
about that fact with slowly flashing LED marked with the number of the blocked zone.
Zone blocking:
1. Enter the number of the function
and press
Note: If incorrect code is entered the keyboard will emit long constant
sound. Enter the correct code once again.
2. Using buttons numbered 1 to 7 select zones you want to block.
3. Change the zones blocking status by pressing numbered buttons (LEDs with relevant
zone number will go on/off). Press
will confirm the change. To cancel the entered changes, press

4.2. ADDING A NEW USER

You can add a new user code here. New codes can be added by the administrator only. 3
beeps will confirm the successfully entered function.
Note: Individual codes cannot be the same; if any code is the same as
another one, it will not be recorded.
To add a new user:
1. Enter the function code
2. Enter the admin code and confirm it with
input.
3. Numbers of already existing users will be displayed.
4. Enter the ID of newly added user (1 to 8), other than already added ID numbers, and
press
displayed.
5. To activate/deactivate LED of an appropriate partition, press 1 or 2. When the access is
set, press
6. Enter the code of a newly added user (4 to 7 digits) and press
7. Enter the code of a newly added user again and press
exit without saving changes.
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
. 3-tone beep will confirm the correct code input.
to confirm. Numbers of partitions a new user can have access to will be
to confirm. All LEDs shall be off now.
and confirm with
to confirm blocking of selected zones. 3 beeps
and press
to confirm.
. 3 beeps will confirm the correct code
. Enter the user code
.
to confirm.
to finish adding or