10. EXTRAS

10.1. REMOTE COMMANDS AND CONFIGURABLE PARAMETERS

The control unit receives SMS in a specially designed form. If SMS that was received by the
equipment is not correct, it gets automatically deleted and the equipment does not initiate
any activity. The following format of the message is accepted, and it allows sending a few
commands in one SMS message, while each of them must be separated with a SPACE:
ACCESS CODE
where:
ACCESS CODE
code or administrator code. In case the command requires authorisation by administrator
code (e.g. CPGETUSERS), this code should be passed to the command only once, either as
access code or as a parameter passed along with the command. In other words, whenever
access code is not an administrator code and the command has to be authorised by the
administrator code, it has to be passed as a command's parameter.
COMMAND/PARAM - instruction (see the tables below)
The newly configured parameter will be taken into account when the device will need to use
it, there is no need to restart the unit. However, there are parameters, changes to which will
be detected only in special circumstances, for example – the server address. If it is changed
when the device is online, a restart is needed. When CPX200N boots up, it will connect to
the newly configured address.
In order to delete a parameter, the message has to contain the name of the parameter
followed by the equation mark ( = ). For example, to delete the number to which text
messages are sent, one has to send a following text: "XXXX SMS=", where XXXX is the
access code.
ATS – (Alarm Transmission System) – is a special type of user, meaning the monitoring
station. The user is authorized by the main access code to the device (the code to read the
configuration via a cable). ATS is also authorized by encryption keys. If the command is sent
through an encrypted transmission, code is not required.
User – regular user with the ability to arm and disarm the partition to which they have
rights, and other rights described in the user manual. Several regular users may be in the
system.
Administrator – a special user who has privileges to add and delete other users.

10.1.1. Configuration Parameters

10.1.1.1. APN
Format:
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
COMMAND/PARAM
- access code of the equipment, may be either a service code, user
- space
APN=apn_name
COMMAND/PARAM
.........
84 / 106