EBS CPX200N Installation And Programming Manual page 88

Alarm control unit
Table of Contents

Advertisement

10.1.2.6. OUT
Format:
Limitations:
Description
10.1.2.7. FLUSH
Format:
Limitations:
Description
10.1.2.8. SENDSMS
Format:
Limitations:
Description
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
OUT=o,s[,time]
Can be executed only by ATS or administrator
Sets the "s" status on "o" output. The "s" status is equal to 1 for switching
on, and 0 for switching off. If you want to switch on eg. the output 2,
send the command OUT = 2,1. Switching off the output 2 is done by
sending the command OUT = 2,0. If the output is switched on, the
switch-on time is equal to the configured time, or if the time parameter is
specified, the output is switched on for the specified number of seconds.
If the time parameter is equal to 0, the output is bistable switched on ie.
it will be only switched off when you send the command that disables the
output.
FLUSH=x
x is equal to 0 or 1, possible to execution only by ATS
For x = 0 it clears the queue of outstanding events to be sent to the OSM
server. This results in the loss of outstanding events - the device
generates then an event indicating the fact.
For x = 1 it clears the event log of the device.
SENDSMS=phone_no,text_wihout_spaces
This command does not work when sent via SMS; possible to execution
only by ATS
Allows you to send the SMS to the specified phone number (phone_no)
with the specified content. This command is a tool with which you can get
information about the phone number of the SIM card installed in the
device when connected to the OSM server using GPRS.
88 / 106