EBS CPX200N Installation And Programming Manual page 51

Alarm control unit
Table of Contents

Advertisement

7.4.2.1. First programming of the equipment
As no access parameters to GPRS network and OSM.2007 are defined in the
equipment, you shall start the programming with defining the parameters.
Irrespectively of the input method, first you have to register the equipment in the
OSM.2007 database.
Before starting the remote programming, you have to make sure that the SIM card
was inserted (subject to conditions defined in chapter 7.1.5.3) and the equipment
was connected to power supply. The user must know the serial number of the
equipment and SIM card telephone number.
The programming procedure is the following:
 Using the pad of OSM.2007 device, indicate with the cursor the correct equipment
in 'Equipment' tab.
 Click "Config" option and then indicate "Set configuration" function. A list of
parameters will be displayed.
 Enter server address, server port and APN. When clicking OK, the system will send
entered parameters to the equipment (SMS).
 Wait until the equipment reports to the server (in Equipment tab, it will be marked
green).
 Start the software and define the options of the equipment (for description, please
refer to chapter 7).
 Select Send function. The window will appear where you have to select the
previously defined remote connection (chapter 6.3.1.5.2). Copy the settings into
the memory of the equipment.
 Close the configuration wizard's window after you finish the data input.
 The equipment is ready for data transmission.
7.4.2.2. Reprogramming of equipment.
As access parameters to GPRS network and OSM.2007 are defined in the equipment,
you can proceed with programming any time.
If the equipment is installed in a secured facility, i.e. it has a SIM card inserted and it
is connected to power supply, the programming procedure in the following:
 Start the configuration wizard software and define the options of the equipment
(for description, please refer to chapter 7).
 Select Send function. The window will appear where you have to select the
previously defined remote connection (chapter 6.3.1.5.2). Copy the settings into
the memory of the equipment.
 Close the configuration wizard's window after you finish the data input.
 The equipment is ready for data transmission in accordance with new settings.
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
51 / 106