Partitions - EBS CPX200N Installation And Programming Manual

Alarm control unit
Table of Contents

Advertisement

8.3.2.

Partitions

8.3.2.1. Partittion 1 / 2
In that tab you can assign the zones from 1 to 7 to the specific monitoring partitions.
If the zone is not assigned to any of the partitions (and it is not of 24H type), all
events received from that zone (disruption/return) will be ignored.
8.3.2.2. Entrance / Exit
The parameter allows switching off the indication of time for entrance / exit displayed
by KP10 keypad.
8.3.2.3. Time for exit
It is time for leaving the partition. Assigned zones will be active (monitored) after the
expiration of pre-defined time, counting from the time the arming zone was
disrupted.
8.3.2.4. Alarm time
The parameter defines the time the alarm will be indicated by KP10 keypad.
8.3.2.5. Partition name
The parameter allows you to give any name for the partition.
CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL