Power Loss; Reset To Default Settings; System Options - EBS CPX200NWB Installation And Programming Manual

Alarm control unit
Table of Contents

Advertisement

Installer code –
You can press
4.3.2.

Power loss

The function determines time in seconds after which failure is to be reported. The function's
argument is of decimal type. 3 beeps will confirm the successfully entered function.
To change /configure the time:
where:
Time –
time in seconds
You can press
4.3.3.

Reset to default settings

That function resets the settings to their default configuration, accessible from the service
mode level. Additionally, the function sets the default output options and default installer
code. The wireless detectors and remote controls are not deleted.
In order to protect the settings against accidental modification, the function is to be
confirmed with installer code. 3 beeps will confirm the successfully entered function. Using
that function will trigger the control unit's reset using default parameters.
You can press
4.3.4.

System options

That function allow to switch on and switch off additional options of the system. The
argument of the function is BIT type. By pressing 1, 2, 3, 4, 5 and 6 keys, you can switch
on/off proper option. 3 beeps will confirm the successfully entered function.
Where:
Options – number of option (BIT type parameter):
 1 – Enable faults memory indication – when is switched off, LED SYSTEM does not
show by blinking the faults that are not active; you can display inactive faults by
choosing "faults memory" user function.
 2 – Disable ATS monitoring. If his option is enabled, ATS failure isn't signaled to the
user in any way on the keypad and it doesn't cause arm prevention.
 3 – Disable automatic arm prevention overriding when fault. If this option is disabled
and at least on fault is active in the system, arm prevention isn't signaled to the user
during partition arming. Instead arm prevention is automatically overridden. If option
is enabled, faults causes arm prevention which can be overridden by user.
 4 – Access to alarm and fault memory requires authorization. If this option is
enabled, checking alarm memory and fault memory is available only after a user code
CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL
new installer code (from 4 to 7 digits)
any time to exit without saving changes.
any time to exit without saving changes.
any time to exit without saving changes.
<Time>
<Installer code>
<Options>
25 / 118