v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
806f0823-2101ffff
806f090c-2001ffff
806f090c-2002ffff
806f090c-2003ffff
806f090c-2004ffff
806f090c-2005ffff
806f090c-2006ffff
806f090c-2007ffff
806f090c-2008ffff
806f090c-2009ffff
806f090c-200affff
806f090c-200bffff
806f090c-200cffff
806f0a07-0301ffff
806f0a07-0302ffff
0x806f0a0c 806f0a0c-2001ffff
806f0a0c-2002ffff
806f0a0c-2003ffff
806f0a0c-2004ffff
806f0a0c-2005ffff
806f0a0c-2006ffff
806f0a0c-2007ffff
806f0a0c-2008ffff
806f0a0c-2009ffff
806f0a0c-200affff
806f0a0c-200bffff
806f0a0c-200cffff
168
BladeCenter HS23E Type 8038 and 8039: Problem Determination and Service Guide
Type
Error Message
Info
Watchdog Timer
interrupt occurred
for sensor (IPMI
Watchdog).
Info
Memory device X,
(DIMM X) memory
Throttled X [Note
X=1-12]
Warning
Processor X (CPU
X) is operating in a
Degraded State.
[Note X=1,2]
Error
Memory device X,
(DIMM X) memory
in critical
over-temperature
state Throttled X
[Note X=1-12]
Action
Information only; no action is required.
1. Check the event logs for fan or cooling
related issues (see "Event logs" on page
96).
2. Make sure that the airflow at the front
and rear of the chassis is not obstructed
and the fillers are in place and correctly
installed.
3. Make sure that the room temperature is
within the operating specifications.
4. Make sure the air baffle and the fan
fillers are installed correctly.
5. If the problem remains and there is no
other DIMM with the same issue, replace
the affected DIMM (see "Removing a
memory module" on page 65 and
"Installing a memory module" on page
66).
1. Check the event logs for fan, cooling, or
power related issues (see "Event logs" on
page 96).
2. Make sure that the airflow at the front
and rear of the chassis is not obstructed
and the fillers are in place and correctly
installed.
3. Make sure that the room temperature is
within the operating specifications.
4. If the problem remains and there is no
other DIMM with the same issue, replace
the affected DIMM (see "Removing a
memory module" on page 65 and
"Installing a memory module" on page
66).
1. Make sure that the room temperature is
within the operating specifications (see
"Features and specifications" on page 7).
2. Make sure that none of the air vents on
the BladeCenter unit and on the blade
server are blocked.
3. Make sure that all of the fans on the
BladeCenter unit are running.
4. Make sure the air baffle and the fan
fillers are installed correctly.