Lenovo BladeCenter HS23E Problem Determination And Service Manual page 143

Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are consumable, structural, or CRU
parts.
v If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code Event ID
0x80010200 80010202-0701ffff
0x80010200 80010202-0701ffff
Type
Error Message
Error
System board
(SysBrd 12V)
voltage (lower
critical) has
asserted.
Error
System board
(CMOS battery)
voltage (lower
critical) has
asserted.
Action
1. If the under voltage problem is occurring
on all blade servers, look for other events
in the log related to power and resolve
those events (see "Event logs" on page
96).
2. View the event log provided by the
advanced management module for your
BladeCenter unit and resolve any power
related errors that might be displayed.
3. If other modules or blades are logging
the same issue then check the power
supply for the BladeCenter unit.
4. If the error still occurs, replace the
system-board assembly (see "Removing
the system-board assembly" on page 90
and "Installing the system-board
assembly" on page 91).
Replace the system battery (see "Removing
the battery" on page 61 and "Installing the
battery" on page 62).