prevented the test from running; for example, there might be a configuration
problem, or the hardware might be missing or is not being recognized.
The result is followed by an error code or other additional information about the
error.

Viewing the test results

Use this information to view the test results of the blade server.
You can use one of the following methods to access the test log when the tests are
completed:
v From the DSA command line, issue the DSA CLI View command or select the
Diagnostic Event Log option from the DSA graphical user interface (GUI)
v From the DSA interactive menu, select the getextendedresults option.
v From the DSA interactive menu, select the View option to view all of the
collected results and error log data.
v In the DSA GUI, select DSA Error Log from the System Information page.
You can send the DSA error log file to IBM service and support to aid in
diagnosing the server problems or you can use the DSA CLI copy command to
copy the log to an external USB device.

Diagnostic messages

Use this information to review the diagnostic error messages and resolve any
errors that might occur in the blade server.
If the diagnostic programs generate error codes that are not listed in the table,
make sure that the latest level of the UEFI code is installed. To download the latest
firmware for the blade server, go to http://www.ibm.com/systems/support/.
The following table describes the messages that the diagnostic programs might
generate and suggested actions to correct the detected problems. Follow the
suggested actions in the order in which they are listed in the action column. In the
error codes, x can be any numeral or letter. However, if the three-digit number in
the central position of the code is 000, 195, or 197, do not replace a component.
These numbers appearing in the central position of the code have the following
meanings:
000
The blade server passed the test. Do not replace a component.
195
The Esc key was pressed to end the test. Do not replace a component.
197
This is a warning error, but it does not indicate a hardware failure; do not
replace a component. Take the action that is indicated in the Action
column, but do not replace a component. See the description for Warning in
the section "Diagnostic text messages" on page 192 for more information.