Sub-Function 00 (0X00) Read Module Name - ICP DAS USA PIR-130-AC User Manual

Hide thumbs Also See for PIR-130-AC:
Table of Contents

Advertisement

3.10.1 Sub-function 00 (0x00) Read Module Name

This sub-function code is used to read the name of the PIR-130 module.
Request
Byte
Description
00
Address
01
Function Code
02
Sub-function Code
Response
Byte
Description
00
Address
01
Function Code
02
Sub-function Code
03 - 06
Module Name
Error Response
Byte
Description
00
Address
01
Function Code
02
Exception Code
PIR-130-AC/DC User Manual Ver. 1.4.0, 2020/07/28
Length
Value
(in Bytes)
1
1 to 247
1
0x46
1
0x00
Length
Value
(in Bytes)
1
1 to 247
1
0x46
1
0x00
4
0x4C 0x43 0x01 0x01
(PIR-130)
Length
Value
(in Bytes)
1
1 to 247
1
0xC6
1
Refer to the Modbus standard for more
details.
88/93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pir-130-dc

Table of Contents