ICP DAS USA PIR-130-AC User Manual page 8

Hide thumbs Also See for PIR-130-AC:
Table of Contents

Advertisement

Power supply
Protection
Power Consumption
Mechanical
Installation
Protection Class
Dimensions (D x H)
Environment
Operating Temp.
Storage Temp.
Humidity
Model
Time Delay (seconds)
LUX Control Level
Detection Range
Detection Field of View
Temperature Sensor
Measuring Range
Fire Alarm
Resolution
Accuracy
Relay Output
Channels
Type
Max. Load Current
Load Wattage
RS-485 Interface
COM Port
Transmission Distance (m)
PIR-130-AC/DC User Manual Ver. 1.4.0, 2020/07/28
100 ~ 240 VAC
Power reverse polarity protection, Over-voltage brown-out
protection
2 W
10 to 90% RH, non-condensing
PIR-130-AC
Hardware: 8-step Switch-selectable: 6, 16, 33, 66, 131, 262,
524, and 1049
Software: 16-step: 2, 4, 6, 8, 16, 33, 49, 66, 131, 262, 393, 524,
1049, 2097, 3146, and 4194
Adjustable from daylight to darkness
Hardware: 2 modes (Dawn and dusk)
Software: 5-step
Radius: 4 meters Max.
360° (Max. Diameter of 8 meters)
-25 to +100°C
65°C (Programmable)
0.0625°C
±2°C
1
Power Relay, Form C
NO: 10 A @ 250 VAC
NC: 6A @ 250 VAC
Incandescent Bulb: 1500 W Max.
Fluorescent Lamp: 300 W Max.
RS-485
Dependent on Baud Rate.
10 ~ 30 VDC
1.3 W
Ceiling mounting
IP20
Ø 121 mm x 52 mm
-25 ~ 75 ℃
-30 ~ 80 ℃
PIR-130-DC
8/93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pir-130-dc

Table of Contents