ICP DAS USA PIR-130-AC User Manual page 77

Hide thumbs Also See for PIR-130-AC:
Table of Contents

Advertisement

0: Inactive
Enables or disables the high temperature alarm..
00262
0: Disabled
1: Enabled
Reads/sets the high temperature alarm type.
00263
0: Momentary Alarm
1: Latch Alarm
Enables or disables Buzzer activation for when the PIR Sensor is
triggered.
00274
0: Disabled
1: Enabled
Reads/sets the high alarm status, write 1 to clear latched
00305
high alarm
30226
Reads/sets the High alarm limits
Reads/sets the PIR Relay Output On Time for when the PIR
Sensor is triggered in hexadecimal format. The valid range is 00
to 0F.
Hex
30513
00
04
08
0C
Reads/sets the Luminance Value for the PIR Sensor. The valid
range is 0 to 4, where.
0: Disabled
30514
1: 100 Lux
2: 200 Lux
3: 500 Lux
4: 1000 Lux
Reads/sets the Active Delay Time for the Relay Output in
30516
milliseconds. The valid range is 0 to 0xBB8 (0 to 3000
milliseconds).
Reads/sets Sensitivity value for the PIR Sensor. The valid range
30517
is 0 to 9, where a lower value denotes a higher sensitivity.
PIR-130-AC/DC User Manual Ver. 1.4.0, 2020/07/28
Secs
Hex
Secs
2
01
4
16
05
33
131
09
262
1049
0D
2097
Hex
Secs
Hex
02
6
03
06
49
07
0A
393
0B
0E
3146
0F
R/W
R/W
R/W
R/W
R/W
Secs
R/W
8
66
524
4194
R/W
R/W
R/W
77/93