FLAGS SETTINGS CONFIGURATIONS

The flags can be programmed in a single window by hitting the 'Flag Settings' icon in the 'Monitor' tab in the GUI and the state
of the power supply can be monitored by clicking on the 'Flags and Readings' icon in the 'Monitor' tab.
This monitor window shows all the fault flags (if any) and the readings in one page. The 'Get First Flag' button determines the
first flag that was set in case of a fault event.
The ADP1046A is programmed to respond to the various fault conditions in the Flag Settings Window.
ACTION: Ignore Flag Completely, Disable Synchronous Rectifiers, Disable ORFET, and Disable power Supply are some of
the operations available in this column.
TIMING: This defines if an ACTION is taken immediately or after a debounce. Debounce is a term used for a wait period in
digital circuitry. After a flag signal is detected, the debounce routine checks if the flag signal remains in its changed state for the
entire programmed debounce period before taking any action. This prevents the ADP1046A from reacting to false positives.
Figure 12 - Fault configurations