ADP1046A 100Watt
Evaluation board
Figure 27 – CS1 Fast OCP programmed to shutdown after 1 fault.
Red trace: SR1 signal
Green and blue trace: OUTD and OUTB PWM signals
Yellow trace: Primary Current
Additional things to try:
a)
Programming an external FLAGIN to trip the CS1 fast OCP comparator.
b)
Enabling/Disabling Volt-Second Balance and its associated gain.
c)
Measuring peak output power at maximum input voltage and by decreasing/increasing the debounce value.
d)
Use a higher CS1 timeout condition with an increased leading edge blanking time.
e)
Choosing a different value of R10 (on schematic) to get a different range of protection.
Figure 28 - Corresponding 'Flags and Readings" window. CS1 Fast OCP was
Rev. 1.3 | Page 19 of 55
PRD1386
the first flag that tripped