Troubleshooting

Carbonisation gas duct flap is stiff

6 Troubleshooting
6.1 Carbonisation gas duct flap is stiff
Operating Instructions SP Dual compact | B1500319_en
Error characteristics
Carbonisation gas duct flap is
stiff
Little or no draught through
the combustion chamber
when the flap is closed
Cleaning the carbonisation gas duct flap
❒ Lift off the controller cover and remove the thermal insulation beneath it
❒ Unfasten the screws on the inspection cover and lift it off
❒ Clean the carbonisation gas duct flap and flap guides and check that they run
smoothly
❒ Clean the entire area using a brush and ash vacuum
Possible cause
Flap guide blocked
Flap cannot be closed due to
dirt and deposits
6
Elimination of error
Check the area under the
inspection cover for dirt and
deposits and clean if
necessary