Operating the system
Operate the boiler using the touch display
4.7.3 Switch pellet unit ON/OFF
Operating Instructions SP Dual compact | B1500319_en
When using more than two store sensors, it is possible to have an information display
with storage tank temperatures in accordance with the number of sensors. An
information display that spans two areas is used.
Pellet unit AUTOMATIC
The pellet unit is activated and starts following a command
from the hydraulic system (storage tank, heating circuit,
domestic hot water...). In so doing, the pellet unit provides heat
until the temperature in the lower storage area has reached a
set value.
During startup the system checks whether there is firewood in
the fuel loading chamber. If existing firewood is ignited, the
pellet unit follows the shutdown procedures and starts with the
cleaning cycle. If there is no firewood in the fuel loading
chamber, pellet operation continues.
Pellet unit OFF
The pellet unit follows the shutdown procedure and starts with
the cleaning cycle. The boiler switches to "OFF" status. All
boiler units are deactivated, heating circuits and domestic hot
water tanks are controlled according to the programs and
times set, the chamber discharge system remains active.
Ignite firewood
⇨ See "Ignite firewood with pellet unit once" [page 31]
4
41