Ignite Firewood With Pellet Unit Once - Fröling SP Dual compact 15 Operating Instructions Manual

Dual fuel boiler
Hide thumbs Also See for SP Dual compact 15:
Table of Contents

Advertisement

Operating the system

Ignite firewood with pellet unit once

4.6 Ignite firewood with pellet unit once
Operating Instructions SP Dual compact | B1500319_en
❒ Close the carbonisation gas duct flap by pulling out the lever
➥ The carbonisation gas duct is closed to provide a better draught during the
heating-up process
❒ Light the paper
If the underpressure from the induced draught fan is too strong for the firing material to
be ignited:
❒ Tap "ID fan off"
➥ The induced draught fan switches off
❒ Light the firing material
❒ Tap "ID fan on"
➥ The induced draught fan switches on
❒ Leave the fuel loading door open for approximately 5 minutes
➥ A bed of embers forms
❒ Close the fuel loading door as soon as a flue gas temperature of approx. 130°C
has been reached
➥ Flue gas temperature is displayed on the boiler display
❒ Tap the standby key in the basic display and select "Ignite firewood"
In submenu (A) set the criteria for starting the ignition:
4
31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP Dual compact 15 and is the answer not in the manual?

This manual is also suitable for:

Sp dual compact 20

Table of Contents