Fröling SP Dual compact 15 Operating Instructions Manual page 32

Dual fuel boiler
Hide thumbs Also See for SP Dual compact 15:
Table of Contents

Advertisement

4
32
Setting
Description
Date and time
The ignition process starts at the set time.
When "daily" is selected, the ignition process starts at the set time every
day.
CAUTION: The status of the hydraulic system is not taken into account!
ignite immediately
The ignition process starts immediately upon closing the fuel loading
door and after the preparation time for the Lambda probe has run out
(approx. 2 minutes).
ext. release
The ignition process starts due to an external release (boiler release
contact at the core module).
Buffer tank min
If the buffer tank temperature falls below a defined value and if the date/
time have been reached, the ignition process starts daily.
Buffer < f.flow
If the buffer tank temperature falls below the maximum flow temperature
setpoint and if the date/time have been reached, the ignition process
starts daily.
NOTICE! In the case of daily ignition, if fuel is not replenished by the preset time the
boiler cannot be started.
NOTICE! See operating instructions for boiler controller for a detailed description.
Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
Operating the system
Ignite firewood with pellet unit once