Residual Risks - Fröling SP Dual compact 15 Operating Instructions Manual

Dual fuel boiler
Hide thumbs Also See for SP Dual compact 15:
Table of Contents

Advertisement

2

2.8 Residual risks

16
WARNING
When the main switch is switched off in heating mode:
The boiler is not controlled. Any resulting boiler malfunctions can cause serious
injury and damage.
Take the following precautions:
❒ Allow the fire to burn out completely and let the boiler cool
➥ ID fan switches off when "Off" status has been reached
(flue gas temperature < 80°C, boiler temperature < 65°C)
❒ Only then is it safe to switch off the main switch
WARNING
When touching hot surfaces:
Severe burns are possible on hot surfaces and the flue gas pipe!
When work is carried out on the boiler:
❒ Shut down the boiler according to procedure ("Off" operating status) and allow
it to cool down
❒ Protective gloves must usually be worn for work on the boiler, and it should
only be operated using the handles provided
❒ Insulate the flue gas pipes and do not touch them during operation
WARNING
When inspecting and cleaning the boiler with the main switch on:
Serious injuries possible due to automatic boiler startup!
Before inspection and cleaning work in/on the boiler:
❒ Switch the boiler off by tapping "Boiler off"
The boiler follows the shutdown procedure and switches to "Off" mode
❒ Allow the boiler to cool for at least 1 hour
❒ Switch off the main switch and take precautions to prevent accidental
switching on
Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
Safety
Residual risks

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP Dual compact 15 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sp dual compact 20

Table of Contents